UTL r-MPPT Solar Management Unit 12V/24V 40A
Key Features
High speed and high performance micro-controller
High speed microcontroller increases the performance of the system. UTL`s Solar Management Unit (SMU) is embed with a high speed microcontroller which provide ability to perform its task more reliably and efficiently.erational life
UTL`s Solar Management Unit (SMU) is highly reliable and it has longer operational life. It can be operated in extreme environment conditions. It can be operated at temperature range that lies in 0°C to 60°C.
Prioritize Solar Power over Grid Power
SMU ensures priority usage of Solar Power over Grid Power to reduce Grid consumption. In Daytime condition, the system will give priority to Solar Power and use Grid Power only when the Solar Power is insufficient to sustain the load requirement. When battery gets fully charged during daytime, the SMU will automatically cut-off the Grid Power from the system and load will run through the home inverter.
Increase the battery lifetime
SMU utilizes four stage battery charging algorithm that enhances the battery life. In Bulk stage SMU feeds the battery installed to it a constant boost charging current until its voltage reaches 14.4V and the float current (which is very close to zero), then in absorption stage it maintains this voltage above 14.2V for 3 hrs. Thus reducing the float current (flowing for the longest period during the entire process) to zero, ultimately resulting in much enhanced battery life keeping it fully charged simultaneously.
Automatic/ Manual operation through a switch
The system can work as a domestic inverter and a solar inverter automatically or manually through a switch except in night condition. In night condition, first it will harvests the stored battery energy then it will work as normal domestic inverter.
Inbuilt protection to avoid battery undercharge and over-charge.
UTL`s SMU has the capability to charge a battery which goes in deep discharge condition. It can charge the battery if the battery voltage during discharge reaches up to 8V per battery. It uses four stages to charge the battery i.e. Boost, Absorption, Float and Equalization. This feature protects the battery for being over charged.
Very Low Consumption in Idle State
UTL`s SMU have very low idle consumption. In idle state it consumes less than 20mA current which makes it more efficient than any other SMU.
Electronic protection
Over charging-voltage
Over charging-current
Under voltage
Battery reverse polarity protection
Solar reverse polarity protection
Reverse current flow at night from battery to solar array
Over temperature
Specification:-
Particulars | Description |
General | |
SMU Capacity | SMU1224/40 |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -20° C to 60°C |
Battery Type | Tubular/SMF, Battery 12V/24V |
Battery Capacity AH | 100AH – 180AH |
Battery charging regulation method | Bulk, Absorption, Float, Equalise |
Electrical | |
Nominal System Voltage | 12/24 DC |
Charging Current (Solar) | 20A-40A |
Charge Controller Efficiency | >95% |
Idle Consumption | <20mA |
Operating Solar Input Voltage (VOC) | 22.5V/45V |
Max. Solar Input Voltage (VOC) | 25A/45V |
Min Solar Input Voltage (VOC) | 15V/30V ± 2% |
Solar Panel Recovery Voltage | 17V/31V ± 2% |
Max. Solar Current | 40A |
Efficiency | >95% |
Battery Set Point @25 °C | |
Absorption voltage Tubular Battery | 14.2V/28.4V±2% |
Absorption voltage SMF Battery | 13.7V/27.4V±2% |
Absorption Duration | 3hr |
Float Voltage Tubular Battery | 14V/28±2% |
Float Voltage SMF Battery | 13.7V/27.0V±2% |
Bulk Voltage Tubular Battery | 14.6V/29.2V±2% |
Equalise Voltage | 14.9/29.8V±2% |
Equalise Duration | 3hr |
Equalise Calendar | 28days |
Mains reconnect when Solar not Present | At any Battery Voltage |
Mains reconnect when insufficient solar power | ≤ 11.8V/23.6V ± 2% |
Mains disconnect when sufficient solar power for Tubular | ≥ 13.8V/27.6V ± 2% |
Mains disconnect when sufficient solar power for SMF | 13.7V/27.4V ± 2% |
Physical | |
Fixing | Wall Mounted |
Weight | 1.5Kg |
Ingress Protection | IP-20 |
Dimension | 228X152X76 mm |
BRAND | :UTL (Fujiyama Power Systems Pvt Ltd) |
PRODUCT SALES & SERVICE | : DHAKSHINA KANNADA & UDUPI DISTRICT ONLY |
SALES ENQUIRE CONTACT | : 8762607476 |
SERVICE CENTRE NAME | : SL ELECTRONICS |
SERVICE CENTRE CONTACT NUMBER | : 0824 4114138, 7795214858 |
Toll Free No (All India Service) | : 8510 885 885 |