| Description | Particulars | 
| Solar PCU Capacity | 3KVA 36V | 
| Input Voltage Range (min-max) | 60-140 VDC | 
| Maximum PV Power Recommended | 3KW | 
| Types of Charger | MPPT | 
| Charge Controller Peak Efficiency | 95% | 
| Battery Low Buzzer | 11.2V | 
| Battery Low Cut | 11.0V | 
| Battery High Cut | 16V | 
| Battery Charging Voltage by SPV | 14.5V | 
| Battery Charging Current by SPV | 18A | 
| Battery Charging Voltage by GRID | 14.2V | 
| Battery Charging Current by GRID | 10A | 
| Grid Low Cut Voltage ( IT Load Disable/Enable) | 120/175V | 
| Grid High Cut Voltage ( IT Load Disable/Enable) | 280/255V | 
| Inverter Nominal Output Voltage | 230VAC | 
| Output Supply Phase | 1 phase, 3 wire | 
| Output Waveform | Sine wave | 
| Nominal Frequency | 50.0 HZ | 
| Load Current | 9.1 A | 
| Inverter Peak Efficiency | >88% | 
| Protections | Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse | 
| Display Parameters | Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status | 
| Switches | Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration) | 
| Indications | System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable* | 
| Max Relative Humidity @25*C (non condensing) | 95% | 
| Weight | 39KG | 
| Dimension (L X W X H) | 457 X 254 X 431 mm |